google-site-verification: googlec74bc159fd69a711.html
Alkali-Resistant System’s Mesh Fabric

Product Documents
با مراجعه به سایت تورنیا بهترین انواع توری فایبر گلاس را سفارش داده و به راحتی تحویل میگیرید.
For more information regarding CTech-LLC® products, please contact our team by clicking here.
The CTech-LLC® Alkali-resistant system’s mesh fabric (ARFM™) is made from E-glass woven fabric as its basis mesh, and then should be coated by alkali-resistant agent. With strong elastic modulus and fracture strength, ARFM™ mesh is the ideal material that effectively reinforces cement concrete.
Key Features
- ARFM™ in alkali-resistant system has ability to resist the alkalinity of the base coats.
- Good dimensional stability, stiffness, smooth and not easy to shrinkage and deform, excellent positioning.
- Water resistance.
- Resistance to aging and attack from breakdown.
- Cable of meeting a variety of requirements..
- Low weight.
- High mechanical strength.
Applications
CTech-LLC® ARFM™ is used for several structural and non-structural interventions, among them we can include:
- As an integral part of the structure in exterioriInsulation finishing systems)
- Strengthen waterproof medium.
- Reinforcing concrete cement.
Storage Conditions
Store product in a dry area with no exposure to moisture.
Shelf Life
Shelf life is 10 years.
Options
Product Code | Unit | aRFM™110 | ARFM™125 | ARFM™145 | ARFM™200 |
---|---|---|---|---|---|
Total Weight | gsm | 110 | 125 | 145 | 200 |
Mesh Size | per inch*inch | 6*4 | 2.5*2.5 | 5*5 | 3*3 |
Tensile Strength in Standard Condition warp/weft | N/50 mm | 1700 / 1600 | 2400 / 2400 | 2000 / 2000 | 3200 / 3200 |
Elongation in Standard Condition warp/weft | % | 4 / 4 | 3.5 / 3.5 | 3.8 / 3.8 | 3.5 / 3.5 |
NOTE: other types of fiberglass meshes are available by customer’s order
Codes and Standards
ACI, 2018, Report on Ferrocement, ACI 549R-18, American Concrete Institute, Farmington Hills, MI.
Waranty
CTech-LLC® warrants its products to be free from manufacturing defects. Buyer determines suitability of product for use and assumes all risks. Buyer’s sole remedy shall be limited to replacement of product. Any claim for breach of this warranty must be brought within one month of the date of purchase. CTech-LLC® shall not be liable for any consequential or special damages of any kind, resulting from any claim or breach of warranty, breach of contract, negligence or any legal theory. The Buyer, by accepting the products described herein, agrees to be responsible for thoroughly testing any application to determine its suitability before utilizing.
Related Literature
Slab Strengthening and Repair with FibraOne™ System
Design/construction errors, excessive deflection, and loss of reinforcement due to corrosion often demand strengthening of RC slabs. Additionally, strengthening may be […]
May

Wall Strengthening and Repair with FibraOne™ System
The strengthening or retrofitting of existing walls to resist higher design loads, correct cracks due soil settlements, correct cracks on walls […]
May
Column Strengthening and Repair with FibraOne™ System
Insufficient and/or poorly defined reinforcement in concrete columns has resulted in catastrophic collapse of many buildings in recent earthquakes. Additionally, strengthening […]
May

Beam Strengthening and Repair with FibraOne™ System
Design/construction errors, excessive deflection, and loss of reinforcement due to corrosion often demand strengthening of RC beams. Additionally, strengthening may be […]
May
آخرین دیدگاهها